Results 1 - 20 de 91
Filter
1.
Rev. bras. oftalmol ; 82: e0043, 2023. tab, graf
Article in English | LILACS | ID: biblio-1507881

ABSTRACT

ABSTRACT LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative risk factor for ectasia. The objective of this study was to assess flap thickness and calculate percentage tissue altered to check if unexpectedly thicker flaps and higher percentage tissue altered could pose as risk factors of ectasia. Four subjects (eight eyes) were submitted to mechanical LASIK in 2009 and 2010. Pre and postoperative clinical and tomographic data were reviewed. Mean preoperative estimated percentage tissue altered was 39.18±1.31%, which was borderline for increased ectasia risk when considering the limit of 40%. However, when considering the postoperatively measured flap thickness, the actual mean percentage tissue altered turned out to be 45.17 ± 4.13%, which was significantly higher than predicted preoperatively (p=0.002). Unexpectedly higher postoperative percentage tissue altered may be responsible for corneal ectasia after mechanical LASIK.


RESUMO A LASIK é um procedimento cirúrgico refrativo, no qual um retalho corneano é criado para expor o leito estromal corneano. A estimativa pré-operatória da espessura do retalho corneano é necessária para calcular o percentual de tecido alterado no LASIK, um importante fator de risco quantitativo para ectasia. O objetivo deste estudo foi avaliar a espessura do retalho e calcular o percentual de tecido alterado para verificar se retalhos inesperadamente mais espessos e percentuais de tecido alterado mais altos poderiam representar fatores de risco de ectasia. Quatro indivíduos (oito olhos) foram submetidos à LASIK mecânica em 2009 e 2010. Dados clínicos e tomográficos pré e pós-operatórios foram revisados. A média de percentual de tecido alterado pré-operatória estimada foi de 39,18±1,31%, limítrofe para risco aumentado de ectasia quando considerado o limite de 40%. No entanto, ao considerar a espessura do retalho medida no pós-operatório, o percentual de tecido alterado médio real foi de 45,17±4,13%, ou seja, significativamente maior do que o previsto no pré-operatório (p=0,002). O percentual de tecido alterado pós-operatóriao inesperadamente mais alto pode ser responsável pela ectasia da córnea após LASIK mecânico.


Subject(s)
Humans , Male , Female , Adult , Postoperative Complications , Surgical Flaps/pathology , Keratomileusis, Laser In Situ/adverse effects , Keratomileusis, Laser In Situ/methods , Dilatation, Pathologic/etiology , Lasers, Excimer/adverse effects , Refractive Errors , Cornea/surgery , Cornea/pathology , Corneal Topography/methods , Tomography, Optical Coherence , Dilatation, Pathologic/diagnosis , Refractive Surgical Procedures/methods , Lasers, Excimer/therapeutic use
2.
Rev. bras. oftalmol ; 81: e0058, 2022. tab
Article in English | LILACS | ID: biblio-1394861

ABSTRACT

ABSTRACT Objective To analyze and describe the coefficients found on maximum Ambrósio Relational Thickness-Maximum (ART-Max) and Belin/Ambrósio Enhanced Ectasia Display total deviation (BAD-D) in eyes with normal corneal topography subjected to cataract surgery with premium intraocular lens implantation and correlated these data with final visual acuity. Methods ART-Max and BAD-D data from 103 eyes of patients subjected to implantation of diffractive bifocal intraocular lens, with normal corneal topography who achieved visual acuity of 20/20 or 20/25 without correction after cataract surgery were analyzed. The groups with normal and abnormal values were compared using the chi-square test. Results Thirty-two (31.1%) and 71 (68.9%) eyes presented normal and abnormal ART-Max values, respectively. The difference between these groups was significant (p=0.0002). Fifty-five (53.4%) and 48 (46.6%) eyes had normal and abnormal BAD-D, respectively, and intergroup difference was not significant (p=0.9576). Conclusion Among patients with normal corneal topography who underwent premium intraocular and had good final visual acuity of 20/20 or 20/25, suspicious or abnormal indices of ART-Max and BAD-D were frequent, providing evidence that it possibly should not be a contraindication.


RESUMO Objetivo Analisar e descrever os coeficientes numéricos encontrados nos exames Ambrósio Relational Thickness-Maximum (ART-Max) e desvio total do Belin/Ambrósio Enhanced Ectasia Display (BAD-D) em olhos com topografia normal submetidos ao implante de lente intraocular premium na cirurgia de catarata, correlacionando-os com a acuidade visual final pós-operatória. Métodos Foram analisados os resultados de ART-Max e BAD-D de 103 olhos de pacientes submetidos ao implante de lentes bifocais difrativas, que apresentavam exame topográficos normal e alcançaram acuidade visual 20/20 ou 20/25 sem correção visual no pós-operatório final. Para a análise estatística entre os grupos normais e anormais ou suspeitos, utilizou-se o teste do qui-quadrado. Resultados Foram encontrados 32 (31,1%) olhos com ART-Max normal e 71 (68,9%) com ART-Max suspeito/anormal. A diferença entre os grupos foi significativa (p=0,0002). Quanto ao BAD-D, foram encontrados 55 (53,4%) olhos com resultados normais e 48 (46,6%) com resultados suspeitos/anormais. A diferença entre os grupos não foi significativa (p=0,9576). Conclusão Entre os pacientes com topografia normal submetidos ao implante de lentes premium e que alcançaram acuidade visual 20/20 ou 20/25, os índices suspeitos ou anormais de ART-Max e BAD-D eram frequentes, não se configurando em contraindicação para a realização do implante.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Refractive Errors/prevention & control , Visual Acuity/physiology , Cornea/pathology , Corneal Diseases/diagnosis , Corneal Topography/methods , Dilatation, Pathologic/diagnosis , Postoperative Complications , Cataract Extraction/adverse effects , Retrospective Studies , ROC Curve , Corneal Diseases/etiology , Lens Implantation, Intraocular/adverse effects , Corneal Pachymetry/methods
3.
Medisan ; 25(3)2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1287302

ABSTRACT

Introducción: La operación de pterigión se exige como habilidad desde el primer año de residencia y la evaluación topográfica es clave para evaluar las modificaciones corneales y perfeccionar las habilidades clinicoquirúrgicas de los cirujanos en formación. Objetivo: Determinar las modificaciones corneales en pacientes operados de pterigión en el Centro Oftalmológico de Santiago de Cuba. Métodos: Se realizó un estudio descriptivo, prospectivo y transversal de 53 pacientes operados de pterigión en el Centro Oftalmológico de Santiago de Cuba, desde enero de 2019 hasta igual mes de 2021, a los cuales se les evaluó topográficamente antes y después de la intervención quirúrgica. Resultados: Predominaron el sexo femenino (60,4 %), el grupo etario de 40-49 años (5,8 %), el grado II de la enfermedad (43,4 %) y el astigmatismo inducido como complicación más frecuente (33,9 %). El poder corneal promedio sufrió variación de 43,25D a 45,75D y el astigmatismo topográfico descendió de 4,75 a 3,55 D. Conclusiones: Con el uso de la topografía se comprobó que existen modificaciones corneales importantes derivadas de la invasión del pterigión en la córnea y de la manipulación quirúrgica.


Introduction: Pterigium surgery is demanded as a skill in the first year of the residency and the topographical evaluation is a key element to evaluate corneal modifications and to improve clinical -surgical skill of training surgeons. Objective: To determine the corneal modifications in patients with pterigium surgery in the Ophthalmological Center from Santiago de Cuba, from January 2019 to the same month in 2021, in whom a topographical evaluation was carried out before and after the surgical procedure. Results: Female sex (60.4 %), age group 40-49 (5.8 %), the disease grade II (43.4 %) and induced astigmatism as the most frequent complication (33.9 %) predominated. Average corneal power suffered a variation of 43.25 D and 45.75 and the topographical astismatism decreased from 4.75 to 3.55 D. Conclusions: With the use of topography it was proven that there are corneal modifications derived from pterigium invasion to the cornea and from the surgical manipulation.


Subject(s)
Professional Competence , Pterygium/surgery , Astigmatism , Corneal Topography/methods
4.
Rev. bras. oftalmol ; 80(1): 71-76, jan.-fev. 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1251315

ABSTRACT

RESUMO O artigo tem como objetivo descrever de forma prospectiva diferentes casos de ectasias altamente assimétricas (very asymmetric ectasia, VAE) para diferenciar formas subclínicas ou "frustas" do ceratocone (forme fruste keratoconus - FFKC) de casos de doença ectásica unilateral. O Caso 1 é um paciente de 39 anos, que admitiu ter coçado intensamente apenas o olho direito (OD) na juventude, se apresentando com ectasia unilateral tratada com sucesso por meio de implante de anel intraestromal em OD. O olho esquerdo (OE) apresentou-se normal ao exame completo por meio de propedêutica multimodal e acuidade visual não corrigida (AVsc) de 20/20, estável por mais de 5 anos, com TBI (tomography and biomechanical index) de 0.02. No Caso 2 é um paciente de 15 anos com ectasia clínica em OD, e OE com topografia normal, mas alterações tomográficas e biomecânicas, incluindo o TBI 0,56, caracterizarando a doença subclínica (FFKC). O Caso 3 é a mãe do paciente do Caso 2, de 46 anos, que se apresentou com presbiopia, sem qualquer histórico oftalmológico relevante. A AVsc foi de 20/20 em cada olho, topografia de Placido com leve encurvamento inferior, mas sem sinais definitivos de ectasia. A avaliação biomecânica e tomográfica revelou sinais de ceratocone em ambos os olhos, com TBI de 1,0 e 0,99. Esses três casos estão de acordo com a definição do consenso global e a hipótese de dois acertos (two-hit hypothesis), que ceratocone é uma doença bilateral, mas ectasia pode ocorrer por causa estritamente mecânica unilateralmente (ou em qualquer olho). A relevância da propedêutica multimodal é destacada, destacando-se a integração do estudo biomecânico e tomográfico com imagens de Scheimpflug.


ABSTRACT The article aims to prospectively describe different cases of highly asymmetric ectasia (very asymmetric ectasia, VAE) to differentiate subclinical or "frustrated" forms of keratoconus (forme fruste keratoconus - FFKC) from cases of unilateral ectatic disease. Case 1 is a 39-year-old patient with unilateral ectasia treated with an intrastromal ring implant. The contralateral eye was normal due to multimodal propaedeutics, stable for more than 3 years, with a TBI of 0.02. The patient admitted to having intensely scratched only his right eye in his youth. In Case 2, a 15-year-old patient with clinical ectasia in the right eye, had a left eye with normal topography and tomographic and biomechanical changes characterizing FFKC. Case 3 is the mother of the case 2 patient, aged 46, who presented with presbyopia, without any relevant ophthalmological history. Uncorrected visual acuity of 20/20 in each eye, Placido topography with slight lower curving, but without definitive signs of ectasia. The biomechanical and tomographic evaluation revealed signs of keratoconus in both eyes. These three cases are in accordance with the definition of the global consensus: keratoconus is a bilateral disease, but ectasia can occur because of strictly mechanical unilateral (in any eye). The relevance of multimodal refractive imaging is highlighted, with a focus on integrating biomechanical and tomographic assessments with Scheimpflug images.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Biomechanical Phenomena , Tomography/methods , Corneal Topography/methods , Dilatation, Pathologic , Keratoconus/diagnosis , Epidemiology, Descriptive
5.
Rev. bras. oftalmol ; 79(6): 420-425, nov.-dez. 2020. tab, graf
Article in Portuguese | LILACS | ID: biblio-1156163

ABSTRACT

Resumo Objetivo: Realizar uma revisão sobre o diagnóstico do ceratocone, com enfoque nos métodos propedêuticos disponíveis. Métodos: Foi realizada uma pesquisa no banco de dados PubMed com as palavras chave: Keratoconus, diagnosis, topography e tomography. Por se tratar de uma revisão, não houve restrição de período para a publicação dos artigos selecionados. Foram também utilizados o manual Prefered Practice Pattern(PPP) da academia americana de oftalmologia, assim como o site "eyewiki.aao.org". Resultados: Dos 641 artigos encontrados no PubMed, assim como os usados como referência para o PPP, 36 foram selecionados por serem considerados mais relevantes para o tema proposto. O site "eyewiki.aao.org" foi utilizado como referência para as figuras. Conclusão: O diagnóstico do ceratocone evoluiu consideravelmente desde quando foi primeiramente descrito. É desejável que seja feito em suas fases precoces devido ao alto potencial de morbidade desta doença. Uma possível integração entre os múltiplos índices diagnósticos, investigação genética, biologia molecular e inteligência artificial é almejado para uma maior acurácia diagnóstica.


Abstract Objective: To Perform a review on the diagnosis of keratoconus, focusing on the available propaedeutic methods. Methods: A search was performed in the PubMed database using the key words: Keratoconus, diagnosis, topography and tomography. As it is a review, there was no restriction regarding the publication period of the selected articles. Furthermore, both the preferred practice pattern(PPP) manual of the American Academy of Ophthalmology, as well as the website "eyewiki.aao.org" were used as reference. The project was submitted to the research ethics committee of the Federal University of São Paulo / UNIFESP / SP 2018 (# 2,568,770). Results: Out of the 641 papers found in PubMed, in adition to those used as a reference for PPP, 36 were selected while considered more relevant to the adopted theme. The website "eyewiki.aao.org" was used as a reference for the images. Conclusion: The diagnosis of keratoconus has evolved considerably since it was first described. It is desirable to diagnose it on the early stages due to its high potential of morbility. A possibility of an integration between the various diagnostic indices, genetic research, molecular biology and artificial intelligence is recommended for greater diagnostic accuracy.


Subject(s)
Humans , Male , Adolescent , Middle Aged , Tomography/methods , Corneal Topography/methods , Keratoconus/diagnosis , Biomechanical Phenomena , Dilatation, Pathologic
6.
Arq. bras. oftalmol ; 83(2): 92-97, Mar.-Apr. 2020. tab
Article in English | LILACS | ID: biblio-1088968

ABSTRACT

ABSTRACT Purpose: To analyze subclinical keratoconus topography indexes using Pentacam and Orbscan-II measurements to identify evidences for seeking sensitive indexes to screen and diagnose subclinical keratoconus. Methods: Fifty healthy participants (50 eyes) and 40 patients with subclinical keratoconus (40 eyes) were included. Seven common parameters including corneal thickness at the thinnest point; minimum curvature of the front surface (minimum simulated keratometry value, SimK's Min); maximum curvature of the front surface (maximum simulated keratometry value, SimK's Max); the frontal corneal surface best-fit spherical radius of the curvature; the back corneal surface best-fit spherical radius of curvature; the anterior corneal surface height (anterior Diff value); and the posterior corneal surface height (posterior Diff value) measured by Pentacam and Orbscan-II between normal and subclinical keratoconus eyes were compared. Results: Statistical differences between the healthy and subclinical keratoconus groups (p<0.01) were found in all corneal parameters measured using both devices. Differences in the minimum curvature of the front surface (SimK's Min), thinnest point, anterior Diff value, and posterior Diff value were significant between Pentacam and Orbscan-II in the subclinical keratoconus group (p<0.05). Conclusion: The findings of this study identify the differences between normal and subclinical keratoconus eyes at the minimum curvature of the front surface, maximum curvature of the front surface, frontal corneal surface best-fit spherical radius of curvature, back corneal surface best-fit spherical radius of curvature, Anterior Diff value, and Posterior Diff value measures using Orbscan II and Pentacam that can help eye care practitioners clinically diagnose subclinical keratoconus.


RESUMO Objetivo: Analisar os índices subclínicos de to pografia de ceratocone utilizando as medidas feitas com Pentacam e com Orbscan-II para identificar evidências para a busca de índices sensíveis para triagem e diagnóstico de ceratocone subclínico. Métodos: Cinquenta participantes saudáveis (50 olhos) e 40 pacientes com ceratocone subclínico (40 olhos) foram incluídos. Sete parâmetros comuns, incluindo a espessura da córnea no ponto mais fino; a curvatura mínima da superfície frontal (valor mínimo da ceratometria simulada, Min de SimK); a curvatura máxima da superfície frontal (valor máximo da ceratometria simulada, Max de SimK); a superfície frontal e a superfície posterior da córnea de melhor ajuste ao raio da curvatura, a altura da superfície anterior da córnea (valor Diff anterior) e a altura da superfície corneana posterior (valor Diff posterior) medidos pelo Pentacam e pelo Orbscan-II entre os olhos normais e com ceratocone subclínico foram comparados. Resultados: As diferenças estatísticas entre os grupos saudável e com ceratocone subclínico (p<0,01) foram encontradas em todos os parâmetros corneanos medidos usando ambos os dispositivos. Diferenças na curvatura mínima da superfície frontal (Min de SimK) no ponto mais fino, no valor Diff anterior e no valor Diff posterior foram significativas entre Pentacam e Orbscan-II no grupo com ceratocone subclínico (p<0,05). Conclusão: Os achados deste estudo identificam as diferenças entre olhos normais e com ceratocone subclínico para a curvatura mínima da superfície frontal, a curvatura máxima da superfície frontal, a superfície corneana frontal e a superfície corneana posterior de melhor ajuste ao raio esférico da curvatura e as medidas de Diff anterior e posterior usando Orbscan II e o Pentacam que podem auxiliar os profissionais de oftalmologia a diagnosticar clinicamente o ceratocone subclínico.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Young Adult , Cornea/pathology , Cornea/diagnostic imaging , Corneal Topography/instrumentation , Keratoconus/pathology , Keratoconus/diagnostic imaging , Reference Values , Case-Control Studies , Prospective Studies , Reproducibility of Results , Statistics, Nonparametric , Corneal Topography/methods
7.
Rev. bras. oftalmol ; 79(2): 95-98, Mar.-Apr. 2020. tab, graf
Article in Portuguese | LILACS | ID: biblio-1137937

ABSTRACT

Resumo Objetivo: Avaliar o astigmatismo induzido pela cirurgia de catarata através da técnica de facoemulsificação (FACO) guiada pelo planejador cirúrgico VERION®, em um serviço oftalmológico do Paraná. Métodos: O estudo tem caráter observacional com avaliação individualizada de prontuários de forma retrospectiva, analisando 37 olhos de 20 pacientes operados de catarata pela técnica de FACO com a utilização do VERION® e implantação de lente não-tórica no Hospital de Olhos de Cascavel - PR no período de maio de 2016 a novembro de 2018. Resultados: Dentro de nossa amostra composta por 37 olhos abordados com assistência do VERION®, 43% dos participantes do estudo (n=16) apresentaram redução do astigmatismo inicial, inclusive com eliminação de graus mais graves de astigmatismo (≥2.5 D). Conclusão: O impacto do VERION® foi significativo uma vez que permitiu a correção do astigmatismo prévio de uma parte da amostragem. Em olhos que ocorreram astigmatismo induzido cirurgicamente essa complicação foi menos relevante clinicamente em comparação com incisões corneanas da técnica convencional.


Abstract Objective: To evaluate the astigmatism induced by cataract surgery through the phacoemulsification (PHACO) technique guided by the VERION® surgical planner, in an ophthalmological service of Paraná. Methods: This is an observational study with retrospective individualized evaluation of medical records, analyzing 37 eyes of 20 patients who underwent cataract surgery using the PHACO technique using VERION® and non-toric intraocular lens implantation at the Hospital de Olhos de Cascavel - PR in May 2016. Results: Within our sample of 37 eyes approached with VERION® assistance, 43% of study participants (n=16) had reduced initial astigmatism, including elimination of more severe degrees of astigmatism (≥2.5 D). Conclusion: The impact of VERION® was significant as it allowed the correction of previous astigmatism of a part of the sample. In eyes that had surgically induced astigmatism, this complication was less clinically relevant compared to conventional technique corneal incisions.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Astigmatism/complications , Astigmatism/epidemiology , Cataract Extraction/adverse effects , Phacoemulsification/methods , Surgery, Computer-Assisted , Retrospective Studies , Corneal Topography/methods , Observational Study
8.
Arq. bras. oftalmol ; 82(6): 507-510, Nov.-Dec. 2019. tab
Article in English | LILACS | ID: biblio-1038689

ABSTRACT

ABSTRACT Purpose: The aim of this study was to evaluate anterior segment parameters and corneal aberrations in patients with retinitis pigmentosa using Scheimpflug imaging and to compare the findings with those for healthy controls. Methods: This single-center, case-control study included patients diagnosed with retinitis pigmentosa who were followed up at the Department of Ophthalmology of Kayseri Training and Research Hospital between February and June 2018. Age- and sex-matched healthy individuals with no known ophthalmologic disease formed the control group. Both patients with retinitis pigmentosa and controls underwent comprehensive ophthalmic assessments, including the measurement of the best-corrected visual acuity calculation of the spherical equivalent, slit-lamp examination, stereoscopic fundus examination, computerized visual field test, and electroretinography. Topographic and aberrometric values were measured using Scheimpflug-based tomography. Results: This study was performed on 52 eyes of 26 patients with retinitis pigmentosa (14 men) and 52 eyes of 26 healthy controls (11 men). The average keratometry (K avg) values for the patient and control groups were similar (43.87 ± 2.23 versus 43.61 ± 1.68; p=0.546), but the maximum keratometry (K max) value was significantly higher in the patient group (45.85 ± 2.35 and 44.69 ± 1.86; p=0.015). Patients with retinitis pigmentosa had a significantly lower central corneal thickness (518.5 ± 42.3 versus 534.1 ± 24.5, respectively; p=0.042) and maximal corneal thickness (509.1 ± 50.5 versus 530.5 ± 24.1, respectively; p=0.015). Additionally, the iridocorneal angle for the patients was significantly lower (31.6 ± 9.2 versus 35.9 ± 7.7, p=0.025). The aberrometric findings indicated that patients with retinitis pigmentosa had significantly more higher-order aberrations than those in the healthy controls (0.794 ± 51 and 0.398 ± 08, respectively; p<0.001). Conclusions: The results of the present study demonstrated that patients with retinitis pigmentosa have different anterior segment parameters and corneal aberrations compared to healthy controls. These results should be supported by further studies.


RESUMO Objetivo: Este estudo visou avaliar parâmetros do segmento anterior e aberrações corneanas em pacientes com retinite pigmentosa através de imagens de Scheimpflug e comparar os achados com os de controles saudáveis. Métodos: Este foi um estudo caso-controle unicêntrico que incluiu pacientes com o diagnóstico de retinite pigmentosa em acompanhamento no Departamento de Oftalmologia do Hospital de Treinamento e Pesquisa de Kayseri, entre fevereiro e junho de 2018. Indivíduos saudáveis pareados por idade e sexo, sem nenhum conhecimento da doença oftalmológica formou o grupo controle. Ambos os pacientes com retinite pigmentosa quanto os controles foram submetidos a avaliações oftalmológicas abrangentes, incluindo a medição do cálculo da acuidade visual melhor corrigida, o cálculo do equivalente esférico, biomicroscopia, fundoscopia estereoscópica, campimetria computadorizada e eletrorretinografia. Os valores topográficos e de aberrometria foram medidos através de tomografia baseada no sistema Scheimpflug. Resultados: O estudo incluiu 52 olhos de 26 pacientes com retinite pigmentosa (14 homens) e 52 olhos de 26 controles saudáveis (11 homens). Os valores médios da ceratometria (K avg) para grupos dos pacientes e controle foram semelhantes (43,87 ± 2,23 versus 43,61 ± 1,68, p=0,546), mas o valor máximo da ceratometria (K max) foi significativamente maior no grupo de pacientes (45,85 ± 2,35 e 44,69 ± 1,86; p=0,015). Pacientes com retinite pigmentosa apresentaram uma espessura corneana central significativamente menor (518,5 ± 42,3 versus 534,1 ± 24,5, respectivamente; p=0,042) e espessura corneana máxima (509,1 ± 50,5 verus 530,5 ± 24,1, respectivamente; p=0,015). Além disso, o ângulo iridocorneano para os pacientes foi significativamente menor (31,6 ± 9,2 versus 35,9 ± 7,7; p=0,025). Os achados da aberrometria indicaram que os pacientes com retinite pigmentosa apresentaram significativamente mais aberrações de ordem superior em comparação com os controles saudáveis (respectivamente 0,794 ± 51 e 0,398 ± 08, respectivamente; p<0,001). Conclusões: Os resultados do presente estudo demonstraram que pacientes com retinite pigmentosa têm diferentes parâmetros do segmento anterior e aberrações corneanas em comparação com controles saudáveis. Estes resultados precisam ser confirmados por novos estudos.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Retinitis Pigmentosa/pathology , Cornea/pathology , Anterior Chamber/pathology , Reference Values , Case-Control Studies , Retinitis Pigmentosa/diagnostic imaging , Statistics, Nonparametric , Cornea/abnormalities , Cornea/diagnostic imaging , Corneal Topography/methods , Aberrometry/methods , Corneal Pachymetry/methods , Anterior Chamber/diagnostic imaging
9.
Arq. bras. oftalmol ; 82(6): 488-494, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1038692

ABSTRACT

ABSTRACT Purpose: This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%. Methods: Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures >65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups. Results: The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01). Conclusions: Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes.


RESUMO Objetivos: Este estudo aborda os resultados refrativos, topográficos, acuidade visual e tomografia de coerência óptica, 12 meses após a inserção do segmento de Anel de Ferrara em túnel corneano a 60% de profundidade com o laser de femtosegundo, em pacientes com ceratocone. Métodos: Série de casos não comparativos, prospectivos e intervencionistas. Realizamos a inserção do Anel de Ferrara através de incisão com o laser de femtosegundo em 15 olhos ceratocônicos. Foram incluídos pacientes com ceratocone documentado que voluntariamente assinaram consentimentos informados que tivessem melhor acuidade visual corrigida ≥0.30 tabela logMAR, espessura corneana ≥400µm. Foram excluídos pacientes com cirurgia ocular prévia ou curvatura corneana > 65 dioptrias (D). As principais variáveis medidas foram acuidade visual corrigida e os parâmetros topográficos da córnea (ceratometria mais plana (K1), mais curva (K2) e ceratometria média (K médio), avaliadas no pré-operatório e com 1, 3, 6 e 12 meses de seguimento. Resultados: A média ± desvio padrão da acuidade visual sem correção e acuidade visual corrigida foi 1.03 ± 0.46 e 0.42 ± 0.13, respectivamente; o desvio padrão médio de 12 meses, a acuidade visual sem correção e acuidade visual corrigida foram de 0.72 ± 0.37 e 0.31 ± 0.16, respectivamente, sem diferenças significativas (p=0,05 para ambos). A melhora da acuidade visual corrigida foi estatisticamente significante após 3 meses (p=0,02), e após 6 meses (p=0,02). Os valores médios da linha de base K1, K2, e média (K médio) foram 48,35 ± 3,65D, 53,67 ± 3,38D, e 50,84 ± 3,36D, respectivamente. A média de 12 meses ± desvio padrão para K1, K2, e K médio foi 46,53 ± 3,70D, 49,83 ± 3,50 D, e 48,12 ± 3,49D respectivamente, com diferença estatisticamente significativas para todos os 3 parâmetros topográficos (p=0,01). Conclusões: A inserção do Anel de Ferrara a uma profundidade de 60% no estroma corneano produz resultados visuais, refracionais e ceratométricos satisfatórios em olhos com ceratocone.


Subject(s)
Humans , Male , Female , Adult , Refraction, Ocular/physiology , Visual Acuity/physiology , Corneal Stroma/surgery , Prosthesis Implantation/methods , Keratoconus/surgery , Keratoconus/physiopathology , Reference Values , Time Factors , Tonometry, Ocular/methods , Prospective Studies , Treatment Outcome , Statistics, Nonparametric , Corneal Topography/methods , Tomography, Optical Coherence , Corneal Surgery, Laser/methods , Corneal Pachymetry/methods
10.
Rev. cuba. oftalmol ; 32(2): e735, abr.-jun. 2019. tab
Article in Spanish | LILACS | ID: biblio-1093690

ABSTRACT

RESUMEN Objetivo: Determinar las características topoaberrométricas del queratocono. Métodos: Se realizó un estudio observacional descriptivo de corte transversal que comprendió 101 topografías corneales de pacientes diagnosticados de queratocono con el topógrafo corneal Magellan Plug and Play (n= 101 ojos), en el Instituto Cubano de Oftalmología Ramón Pando Ferrer, en el período 2016-2017. Resultados: Los grupos de edades más representados en la muestra fueron de 20-29 y de 30-39 años, con una proporción similar de pacientes en uno y otro sexo. Predominaron los pacientes con queratocono clínico por índice de severidad y con clasificación patológica según índice de predicción con correlación ascendente entre ambos índices. La localización central del cono fue la más frecuente en esta muestra, donde predominaron los valores más elevados de los índices anteriores. Predominó la aberración de alto orden coma en cuanto al valor medio de raíz cuadrática media y la aberración esférica en el valor máximo. Conclusiones: El grupo de edades más representado según la muestra analizada es el de 20 a 39 años, con proporción similar de pacientes en uno y otro sexo. Predominan los pacientes con queratocono clínico por índice de severidad y con clasificación patológica según índice de predicción con correlación ascendente entre ambos índices. La localización central del cono es la más frecuente y es donde existen los valores más elevados de los índices anteriores. Predomina la aberración de alto orden coma en cuanto al valor medio de la raíz cuadrática media y la aberración esférica en el valor máximo de esta(AU)


ABSTRACT Objective: Determine the topoaberrometric characteristics of keratoconus. Methods: A cross-sectional observational descriptive study was conducted of 101 corneal topograms of patients diagnosed with keratoconus obtained with the corneal topograph Magellan Plug and Play (n= 101 eyes) at Ramón Pando Ferrer Cuban Institute of Ophthalmology in the period 2016-2017. Results: The age groups best represented in the sample were 20-29 and 30-39 years, with a similar proportion of male and female patients. A predominance was found of patients with clinical keratoconus by the severity index and with pathological classification by the prediction index, with an ascending correlation between the two indices. Central cone location was the most frequent in the sample, with a prevalence of the highest levels of the aforementioned indices. A high frequency was found of coma higher-order aberration, according to root mean square and maximum spherical aberration values. Conclusions: The age group best represented in the study sample is 20-39 years, with a similar proportion of male and female patients. A predominance is found of patients with clinical keratoconus by the severity index and with pathological classification by the prediction index, with an ascending correlation between the two indices. Central cone location is the most frequent, with a prevalence of the highest levels of the aforementioned indices. A high frequency is found of coma higher-order aberration, according to root mean square and maximum spherical aberration values(AU)


Subject(s)
Humans , Male , Female , Adult , Corneal Topography/methods , Aberrometry/methods , Keratoconus/etiology , Epidemiology, Descriptive , Cross-Sectional Studies , Observational Studies as Topic
11.
Arq. bras. oftalmol ; 82(1): 68-71, Jan.-Feb. 2019. graf
Article in English | LILACS | ID: biblio-973863

ABSTRACT

ABSTRACT The authors describe an unusual association between posterior keratoconus and iris atrophy, confirmed by a complete ocular evaluation, scheimpflug imaging and pachymetric curve. A hypothesis for concomitant findings is discussed.


RESUMO Os autores descrevem a rara associação entre ceratocone posterior e atrofia de íris, confirmada por avaliação oftalmológica completa, imagens de scheimpflug e curva paquimétrica. Sugere-se uma hipótese que explique a concomitância de ambas as alterações.


Subject(s)
Humans , Female , Middle Aged , Iris/pathology , Iris Diseases/complications , Keratoconus/complications , Astigmatism/complications , Astigmatism/pathology , Atrophy , Amblyopia/complications , Amblyopia/pathology , Corneal Topography/methods , Corneal Pachymetry/methods , Keratoconus/pathology
12.
Arq. bras. oftalmol ; 81(6): 471-474, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-973858

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of superior blepharoplasty on the tear film using the corneal topographer Keratograph 5M. Methods: A prospective study was performed of 27 eyes of 14 patients with superior dermatochalasis who underwent superior blepharoplasty between May and June 2016. Conservative upper eyelid blepharoplasty was performed by an en bloc resection of anterior lamellar tissue that included skin, subcutaneous tissue, and the orbicularis oculi muscle. All the eyes were imaged using the noninvasive tear breakup time tools of the Keratograph 5M. The following parameters were recorded in each patient before and 6 weeks after surgery: first noninvasive Keratograph 5M tear breakup time (the time at which the first breakup of tears occurs) and average noninvasive Keratograph 5M tear breakup time (the average time of all breakup incidents). The exclusion criteria were ophthalmological pathology, previous eyelid surgery, use of eye drops, systemic pathology, and medication that interferes with lacrimal tears. Results: The mean age of the patients was 65.1 years (range, 51-84); 86% were female. Student's t-test was used to compare the values of first and average noninvasive Keratograph 5M tear breakup times before and after surgery. The values for first noninvasive Keratograph 5M tear breakup time evaluated before and after surgery were not significantly different (9.04 and 8.71, respectively; p=0.926). The values for average noninvasive Keratograph 5M tear breakup time evaluated before and after surgery were also not significantly different (13.01 seconds and 13.14 seconds, respectively; p=0.835). Conclusions: The results of this pilot study suggest that upper blepharoplasty does not affect tear breakup time according to the objective evaluation of breakup time with the Keratograph 5M.


RESUMO Objetivos: Avaliar o efeito da blefaroplastia superior no filme lacrimal, utilizando o topógrafo de córnea Keratograph 5M. Métodos: Foi realizado estudo prospectivo de 27 olhos de 14 pacientes com dermatocálase superior submetidos à blefaroplastia superior entre maio e junho de 2016. A blefaroplastia palpebral superior conservadora foi realizada por ressecção em bloco de tecido lamelar anterior que incluiu pele, tecido subcutâneo e músculo orbicular do olho. Todos os olhos foram fotografados usando as ferramentas não-invasivas de tempo de ruptura do lacrimal do Keratograph 5M. Os seguintes parâmetros foram registrados em cada paciente antes e 6 semanas após a cirurgia: primeiro tempo não-invasivo de ruptura lacrimal de Keratograph 5M (o tempo em que ocorre o primeiro rompimento dos rasgos) e média não-invasiva do tempo de ruptura lacrimal (tempo médio de todos os incidentes de ruptura). Os critérios de exclusão foram: patologia oftalmológica, cirurgia anterior das pálpebras, uso de colírio, patologia sistêmica e medicação que interfere na ruptura lacrimal. Resultados: A idade média de idade dos pacientes foi de 65,1 anos (variação entre 51-84); 86% eram do sexo feminino. O teste t de Student foi usado para comparar os valores não-invasivos do tempo de ruptura lacrimal do Keratograph 5M e do tempo de ruptura lacrimal não invasivo do mesmo antes e após a cirurgia. Os valores não-invasivos do tempo de ruptura lacrimal do Keratograph 5M avaliados antes e após a cirurgia não foram significativamente diferentes (9,04 e 8,71, respectivamente; p=0,926). Os valores do tempo médio de ruptura lacrimal do Keratograph 5M avaliados antes e após a cirurgia, também não foram significativamente diferentes (13,01 e 13,14 segundos, respectivamente; p=0,835). Conclusão: Os resultados deste estudo piloto sugerem que a blefaroplastia superior não afeta o tempo de ruptura lacrimal de acordo com a avaliação objetiva do tempo de ruptura com o Keratograph 5M.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Tears/diagnostic imaging , Corneal Topography/methods , Blepharoplasty , Tears/physiology , Dry Eye Syndromes/prevention & control , Pilot Projects , Prospective Studies
13.
Rev. bras. oftalmol ; 77(5): 244-247, set.-out. 2018. tab
Article in English | LILACS | ID: biblio-977870

ABSTRACT

Abstract Purpose: To assess the non-invasive tear break-up time (NITBUT) and tear meniscus height (TMH) after instilling the three different types of anesthetic eye drops by Oculus Keratograph 5M. Methods: In this prospective study, 85 healthy subjects (85 eyes) were randomly divided into three groups. The groups were randomly received lidocaine hydrochloride 2%, proparacaine hydrochloride 0.5%, and tetracaine hydrochloride 0.5%. The qualitative and quantitative parameters of tear film were assessed using NITBUT and TMH, respectively. In all groups, the quantity of tear film using TMH was measured in the right eye of subjects, while the quality of tear film using NITBUT was assessed in the left eye. The analysis of variance (ANOVA) was used to compare the difference between before and after the intervention. A P-value < 0.05 was considered significant. Results: Differences for TMH and NITBUT between before and after applying lidocaine hydrochloride 2% were not statistically significant (P > 0.05). The mean values of NITBUT and TMH after the instillation of proparacaine hydrochloride 0.5% showed a significant decrease than before the intervention (P < 0.05). Also, after the use of tetracaine hydrochloride 0.5%, the mean value of NITBUT was significantly increased (P < 0.05), but the mean value of TMH was significantly decreased than before the intervention (P < 0.05). Conclusion: Our study showed that lidocaine hydrochloride 2% as an anesthetic eye drops can be an appropriate choice for eye examinations due to a lack of significant effect on the quantity and quality of tear film.


Resumo Objetivo: Avaliar o tempo de ruptura lacrimal não invasivo (NITBUT) e a altura do menisco lacrimal (TMH) após instilar os três tipos diferentes de colírio anestésico pelo Oculus Keratograph 5M. Métodos: Neste estudo prospectivo, 85 indivíduos saudáveis (85 olhos) foram divididos aleatoriamente em três grupos. Os grupos receberam aleatoriamente cloridrato de lidocaína a 2%, cloridrato de proparacaína a 0.5% e cloridrato de tetracaína a 0.5%. Os parâmetros qualitativos e quantitativos do filme lacrimal foram avaliados utilizando NITBUT e TMH, respectivamente. Em todos os grupos, a quantidade de filme lacrimal utilizando TMH foi medida no olho direito dos sujeitos, enquanto a qualidade do filme lacrimal usando NITBUT foi avaliada no olho esquerdo. A análise de variância (ANOVA) foi utilizada para comparar a diferença entre antes e depois da intervenção. Um valor de P < 0.05 foi considerado significativo. Resultados: Diferenças para TMH e NITBUT entre antes e depois da aplicação de cloridrato de lidocaína a 2% não foram estatisticamente significantes (P > 0.05). Os valores médios de NITBUT e TMH após a instilação de cloridrato de proparacaína a 0.5% mostraram uma diminuição significativa do que antes da intervenção (P < 0.05). Além disso, após o uso de cloridrato de tetracaína a 0.5%, o valor médio de NITBUT foi significativamente aumentado (P < 0.05), mas o valor médio de TMH foi significativamente menor do que antes da intervenção (P < 0.05). Conclusão: Nosso estudo mostrou que o cloridrato de lidocaína a 2% como colírio anestésico pode ser uma escolha apropriada para exames oftalmológicos devido à falta de efeito significativo sobre a quantidade e a qualidade do filme lacrimal.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Ophthalmic Solutions , Propoxycaine/pharmacology , Tears/drug effects , Tetracaine/pharmacology , Corneal Topography/instrumentation , Anesthetics, Local/pharmacology , Lidocaine/pharmacology , Propoxycaine/administration & dosage , Tears/diagnostic imaging , Tetracaine/administration & dosage , Prospective Studies , Cornea/anatomy & histology , Corneal Topography/methods , Diagnostic Techniques, Ophthalmological/instrumentation , Anesthetics, Local/administration & dosage , Lidocaine/administration & dosage
14.
Rev. bras. oftalmol ; 77(5): 268-271, set.-out. 2018. graf
Article in Portuguese | LILACS | ID: biblio-977865

ABSTRACT

Resumo Objetivos: Medir o ângulo lâmbda (AL) em indivíduos no pré-operatório de facectomias, correlacionando a sua presença com o comprimento axial e o esférico dos olhos. Sugerir condutas para o implante de LIO multifocal de acordo com a presença do ângulo lâmbda. Métodos: Estudo transversal em 128 olhos de 74 indivíduos candidatos à cirurgia de catarata para registrar a equivalente presença do ângulo lâmbda. Resultados: Avaliando o ângulo lâmbda observou-se uma correlação positiva (r= 0,559 / p= 0,000) para o tamanho desse ângulo comparando-se os dois olhos. Não houve correlação entre o tamanho do ângulo lâmbda e o equivalente esférico no olho direito (r= -0,027 / p= 0,840), mas foi verificada correlação positiva para o olho esquerdo (r= 0,313 / p= 0,013). A presença da hipermetropia correlacionou com os comprimentos axiais pequenos, assim como a miopia com os grandes. Observou-se correlação negativa entre o tamanho do ângulo lâmbda e o comprimento axial para os dois olhos, sendo de r= -0,249 para o olho direito (p= 0,042) e r= -0,281 para o olho esquerdo (p= 0,018) Conclusões: Houve correlação entre a presença de ângulo lâmbda maior e comprimentos axiais menores para os dois olhos. Para o equivalente esférico hipermétrope houve correlação com a presença de um ângulo lâmbda maior apenas para o olho esquerdo. Esse trabalho sugere parcimônia nos implantes de LIO multifocal na presença de ângulo lâmbda significativo, baseado na teoria que a presença desse ângulo é reguladora do equilíbrio entre as aberrações da superfície corneana versus cristalineanas.


Abstract Objectives: To measure the labral angle (LA) in individuals in the preoperative period of facectomies, correlating their presence with axial length and spherical equivalent of the eyes. Suggest conduits for the implantation of multifocal IOL according to the presence of the lambda angle. Methods: A cross-sectional study of 128 eyes of 74 individuals who were candidates for cataract surgery to record the presence of the lambda angle. Results: A positive correlation (r = 0.559 / p = 0.000) was observed for the angle of this angle by comparing the two eyes. There was no correlation between the size of the lambda angle and the spherical equivalent in the right eye (r = -0.027 / p = 0.840), but a positive correlation was observed for the left eye (r = 0.313 / p = 0.013). The presence of hyperopia correlated with small axial lengths, as did myopia with large ones. There was a negative correlation between the angle of the tongue and the axial length of the two eyes, with r = -0.249 for the right eye (p = 0.042) and = 0.281 for the left eye (p = 0.018). Conclusions: There was a correlation between the presence of a larger lambda angle and smaller axial lengths for both eyes. For the spherical hypermétrope equivalent, there was a correlation with the presence of a larger blunt angle only for the left eye. This work suggests parsimony in multifocal IOL implants in the presence of a significant lamella angle, based on the theory that the presence of this angle regulates the balance between corneal versus crystaline surface aberrations.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Pupil/physiology , Corneal Topography/methods , Lens Implantation, Intraocular , Axial Length, Eye , Multifocal Intraocular Lenses , Lighting , Cataract Extraction/statistics & numerical data , Cross-Sectional Studies , Biometry/instrumentation , Biometry/methods , Preoperative Period , Fixation, Ocular , Ocular Physiological Phenomena
15.
Rev. cuba. oftalmol ; 31(3): 1-12, jul.-set. 2018. ilus
Article in Spanish | LILACS | ID: biblio-985570

ABSTRACT

La cirugía de catarata actual se ha convertido en una cirugía refractiva, pues se busca además la corrección del defecto refractivo tanto esférico como cilíndrico en el mismo proceder y, por tanto, la emetropía sin corrección óptica en todas las distancias. Para esto debemos tener una verdadera lectura del astigmatismo corneal total y una identificación correcta del meridiano a tratar. Hoy en día existen dispositivos de avanzada tecnología capaces de brindar estos y otros datos preoperatorios e intraoperatorios de gran confiabilidad. Algunos de estos sistemas como Verion, Callisto Eye y el TrueGuide, utilizan la topografía corneal con registro del limbo y, luego de capturar una imagen preoperatoria, la recuerdan durante la cirugía para generar el meridiano objetivo en un monitor o a través del microscopio quirúrgico, y de esta manera ayudar en la alineación precisa de la lente intraocular tórica. Incluso pueden ofrecer imágenes tridimensionales en vivo. Otros, por su parte, utilizan la aberrometría de frente de onda intraoperatoria para ayudar al cirujano a elegir el poder de la lente intraocular tórica y luego alinearla, como los sistemas ORA y Holos IntraOp. Estos instrumentos proporcionan retroalimentación refractiva continua en tiempo real para la corrección astigmática en el mismo acto quirúrgico. Sin dudas, estos sistemas son parte de una revolución tecnológica dentro del campo de la cirugía del cristalino actual que posibilitan una mayor precisión y predicción de los resultados refractivos y constituyen elementos imprescindibles si queremos conseguir una cirugía de catarata de excelencia. Se realiza esta revisión con el objetivo de obtener información acerca de los sistemas de imágenes de alta tecnología que se usan hoy día en la cirugía del cristalino y mostrar sus potencialidades para obtener resultados refractivos posoperatorios más exactos(AU)


Current cataract surgery has become refractive surgery, for it is also aimed at correcting both spherical and cylindrical refractive defects in the same procedure, thus achieving emmetropia without optical correction at all distances. For this we must have a true reading of the total corneal astigmatism and a correct identification of the meridian to be treated. Today there are advanced technological devices capable of providing these and other preoperative and intraoperative data with great reliability. Some of these systems, such as Verion, Callisto Eye and TrueGuide, use corneal topography with limbus registration and after capturing a preoperative image, they remember it during surgery to generate the target meridian on a monitor or through the surgical microscope, thus helping achieve precise alignment of the toric intraocular lens. They can even offer live three-dimensional images. Others, such as the ORA and Holos IntraOp systems, use intraoperative wavefront aberrometry to help the surgeon choose the power of the toric intraocular lens and then align it. These instruments provide continuous refractive feedback in real time for astigmatic correction in the same surgical act. Undoubtedly, these systems are part of a technological revolution within the field of current crystalline lens surgery that enable greater precision and prediction of refractive results and are essential elements if we want to achieve cataract surgery of excellence. This review was conducted to obtain information about high-technology imaging systems currently used in crystalline lens surgery, and show their potential to achieve more accurate postoperative refractive results(AU)


Subject(s)
Humans , Cataract Extraction/methods , Technological Development/methods , Corneal Topography/methods , Imaging, Three-Dimensional/statistics & numerical data , Review Literature as Topic
16.
Rev. bras. oftalmol ; 77(2): 65-67, mar.-abr. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-899116

ABSTRACT

Resumo Introdução: O pterígio é uma proliferação de tecido fibrovascular centrípeta, que avança da conjuntiva bulbar em direção ao centro da córnea. A excisão do pterígio pode causar melhora na acuidade visual. A excisão cirúrgica tem como objetivo atingir uma superfície ocular topograficamente regular. A melhora da acuidade visual decorre da alteração do poder refrativo corneano, que é aferido na topografia como alteração do astigmatismo topográfico. O objetivo do estudo foi avaliar a variação do astigmatismo topográfico final após a cirurgia de exérese de pterígio. Métodos: Foi realizado um estudo prospectivo de acompanhamento de pacientes após cirurgia de exérese de pterígio com a realização de topografias corneanas antes e 1 mês após a cirurgia. A população foi do tipo não-probabilística de voluntários, com n de 74 olhos. A amostragem foi por conveniência, sendo oferecida a participação aos pacientes do ambulatório geral de oftalmologia que foram submetidos ao procedimento de exérese de pterígio entre julho e dezembro de 2015. Resultados: Foram realizadas 74 cirurgias no período e 44 foram incluídas na analise estatística. Os valores médios do astigmatismo topográfico (CYL) mostraram redução estatisticamente significativa de 2,715D para 1,448D (p=0,0037). A alteração do meridiano mais curvo (Ks) não mostrou alteração significativa com variação de 45,60 D para 45,32 D (p=0,1050), enquanto o meridiano plano à 90º Ks (Kf) mostrou aumento significativo de 42,86 D para 43,87 D (p=0,0052). A analise isolada dos grupos mostrou que apenas o grupo com pterígios grau 3 sofreu alteração significativa do CYL de 7,12 D para 1,82 D (p=0,0002). Conclusão: A cirurgia resultou em uma redução significativa do astigmatismo topográfico apenas em pacientes com pterígio grau 3, isso em decorrência da redução do aplanamento provocado pelo pterígio.


Abstract Introduction: Pterygium is a centripetal proliferation of fibrovascular tissue, which proceeds from the bulbar conjunctiva towards the center of the cornea. Excision of the pterygium may cause visual acuity improvement and surgical excision aims to achieve a topographically regular ocular surface. The improvement of the visual acuity results from the alteration of the refractive corneal power, that is measured in the topography as alteration of the topographic astigmatism. The objective of this study was to evaluate the variation of the final topographic astigmatism after the pterygium excision surgery. Methods: A prospective study was carried out to follow up patients after pterygium excision surgery with corneal topography before and 1 month after the surgery. The population was of the non-probabilistic type of volunteers, with n of 74 eyes. Sampling was for convenience and participation was offered to patients from the ophthalmology residence outpatient service who underwent pterygium excision between July and December 2015. Results: A total of 74 surgeries were performed in the period and 44 were included in the statistical analysis. Mean values of topographic astigmatism (CYL) showed a statistically significant reduction from 2.715D to 1.448D (p = 0.0037). The change in the more curved meridian (Ks) showed no significant change from 45.60D to 45.32D (p = 0.1050), while the meridian plane at 90º Ks (Kf) showed a significant increase from 42.86D to 43,87D (p = 0.0052). Isolated analysis of the groups showed that only the group with grade 3 pterygia suffered a significant alteration of CYL from 7,12D to 1,82D (p = 0,0002). Conclusion: The surgery resulted in a significant reduction of topographic astigmatism only in patients with grade 3 pterygium, due to the reduction of the flattening caused by the pterygium.


Subject(s)
Humans , Male , Female , Middle Aged , Ophthalmologic Surgical Procedures/methods , Pterygium/surgery , Cornea/diagnostic imaging , Corneal Topography/methods , Postoperative Period , Astigmatism , Visual Acuity , Prospective Studies , Follow-Up Studies
17.
Arq. bras. oftalmol ; 81(2): 110-115, Mar.-Apr. 2018. tab
Article in English | LILACS | ID: biblio-950439

ABSTRACT

ABSTRACT Purpose: To compare the anterior segment parameters of patients with pseudoexfoliation syndrome, patients with pseudoexfoliation glaucoma, and normal subjects. Methods: This prospective, controlled, comparative study included 150 eyes of 150 patients. The patients were divided into the pseudoexfoliation syndrome group, the pseudoexfoliation glaucoma group, and the control group (50 patients in each group). Axial length, central corneal thickness, aqueous depth, anterior chamber depth, lens thickness, K1 and K2 keratometry values, and white to white distance measurements were obtained by optical biometry and compared between the groups. Results: The mean ages of the pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and control patients were 62.18 ± 6.21, 61.80 ± 6.62, and 59.40 ± 6.89 years, respectively. There were no statistically significant differences between the groups in mean age or sex ratio (p>0.05). Mean central corneal thickness was statistically significantly greater, mean aqueous depth and anterior chamber depth were statistically significantly greater, and mean lens thickness was statistically significantly less in the control group than in the pseudoexfoliation syndrome and pseudoexfoliation glaucoma groups (p<0.05). Pairwise comparisons of the pseudoexfoliation syndrome group and the pseudoexfoliation glaucoma group revealed that there were no significant differences between these two groups in central corneal thickness, aqueous depth, anterior chamber depth, and lens thickness (p>0.017). Conclusions: Patients with pseudoexfoliation glaucoma and pseudoexfoliation syndrome had greater lens thickness, shallower aqueous depth and anterior chamber depth, and less central corneal thickness than normal subjects. None of the anterior segment parameters differed between patients with pseudoexfoliation syndrome and patients with pseudoexfoliation glaucoma.


RESUMO Objetivos: Comparar os parâmetros do segmento anterior de casos de síndrome de pseudo-esfoliação, de glaucoma pseudo-esfoliação e de indivíduos normais. Métodos: O presente estudo prospectivo comparativo controlado incluiu 150 olhos de 150 pacientes. Os pacientes foram divididos em três grupos: grupo síndrome de pseudo-esfoliação, grupo glaucoma pseudo-esfoliação e grupo controle (50 em cada grupo). O comprimento axial, a espessura corneana central, a profundidade aquosa, a profundidade da câmara anterior, a espessura da lente, os valores de ceratometria K1 e K2 e as medidas branco a branco, obtidas por biometria óptica, foram comparados entre os grupos. Resultados: As idades médias dos indivíduos do grupo síndrome de pseudo-esfoliação, glaucoma pseudo-esfoliação e controle foram 62,18 ± 6,21, 61,80 ± 6,62 e 59,40 ± 6,89 anos, respectivamente. Entre os grupos, não houve diferenças estatisticamente significativas quanto às idades e ao gênero dos pacientes (p>0,05, para todos). A espessura da córnea central média foi significativamente mais espessa, a profundidade média aquosa e a profundidade da câmara anterior foram significativamente mais profundas e a espessura média da lente foi significativamente mais fina no grupo controle do que nos grupos síndrome de pseudo-esfoliação e glaucoma pseudo-esfoliação (p<0,05, para todos). As comparações por pares do grupo síndrome de pseudo-esfoliação e do grupo glaucoma pseudo-esfoliação (p<0,05, para todos). As comparações por pares do grupo síndrome de pseudo-esfoliação e do grupo glaucoma pseudo-esfoliação não revelaram diferenças significativas entre esses dois grupos quanto à espessura corneana central, à profundidade aquosa, à profundidade da câmara anterior e aos valores de espessura da lente (p>0,017, para cada um). Conclusões: Os casos de glaucoma pseudo-esfoliação e de síndrome de pseudo-esfoliação apresentaram lente mais espessa, menor profundidade aquosa, menor profundidade da câmara anterior e espessura corneana central mais fina do que os indivíduos normais. No entanto, nenhum dos parâmetros do segmento anterior foi diferente entre os indivíduos do grupo síndrome de pseudo-esfoliação e do grupo glaucoma pseudo-esfoliação.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Glaucoma/pathology , Exfoliation Syndrome/pathology , Anterior Eye Segment/pathology , Reference Values , Visual Acuity , Case-Control Studies , Glaucoma/physiopathology , Prospective Studies , Analysis of Variance , Exfoliation Syndrome/physiopathology , Statistics, Nonparametric , Corneal Topography/methods , Corneal Pachymetry/methods , Intraocular Pressure , Anterior Eye Segment/physiopathology
18.
Rev. bras. oftalmol ; 76(2): 61-64, Mar.-Apr. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-899042

ABSTRACT

Resumo Objetivo: Correlacionar o coeficiente de asfericidade com a aberração esférica longitudinal na superfície corneana, correlacionando também cada uma dessas variáveis com a ceratometria média Métodos: Realizou-se um estudo observacional através da coleta de dados pré-operatórios nos prontuários de indivíduos candidatos a facectomia. Os dados coletados se referiam ao sexo e idade, além do Q, LSA da superfície corneana e ceratometria média (Km). Foram excluídos do estudo os pacientes que realizaram qualquer procedimento cirúrgico corneano, por alterar as medidas da Q, LSA e Km. O topógrafo selecionou, de maneira fixa, uma área 4,5mm da superfície anterior da córnea para medida do Q e da LSA, tendo como ponto central o eixo pupilar. A ocorrência da LSA é relevante em ambientes de penumbra, em indivíduos com pupila maior que 3mm. Resultados: A amostra foi composta por 70 olhos de 35 indivíduos: 24 (68,6%) mulheres e 11 (31,4%) homens. A idade variou de 48 a 89 anos (média de 69,97 ± 8,29). A Km variou de 41,00D a 46,50D com média de 43,94 ± 1,48D. Na avaliação do Q da superfície corneana se observou uma média de -0,15 ± 0,15. Seis (8,57%) córneas apresentaram desenho esférico com Q= 0 e apenas uma córnea apresentou desenho asférico com Q= -0,50, gerando LSA= 0,0µm. Em relação a LSA da superfície corneana se observou média de +0,33 ± 0,14 µm. Quarenta e dois olhos (60,0%) apresentaram LSA entre +0,31 a +0,64µm e 19 (27,15%) entre +0,16 a +0,30µm. Não houve correção entre a Km e o Q (r= -0,005 / p= 0,965), assim como entre Km e a LSA (r= 0,167 / p= 0,170). Observou-se correlação (r= 0,962 / p= 0,000) entre as variáveis Q x LSA. Conclusão: Foi observada correlação entre o Q e a LSA da superfície corneana. Não foi observado correlações entre o coeficiente de asfericidade ou aberração esférica longitudinal com a ceratometria média.


Abstract Objective: To correlate the asphericity coefficient (Q) with longitudinal spherical aberration (LSA) of the corneal surface, also correlating each of these variables with the average keratometry Methods: An observational study was conducted by collecting preoperative data from the medical records of individuals candidate cataract surgery, i.e., patient sex and age, as well as Q, LSA of the corneal surface and mean keratometry (Km). Patients who had been subjected to any corneal surgical procedure who would alter Q, LSA and Km measuements were excluded. The corneanl topograph selected, fixedly, a 4.5 mm area of the anterior surface of the cornea for the measurement of Q and LSA, having the pupillary axis as the central point, since the occurrence of LSA is relevant in dim environments in individuals with a pupil wider than 3 mm Results: The sample consisted of 70 eyes of 35 individuals, 24 of them women (68.6%) and 11 men (31.4%) ranging in age from 48 to 89 years (mean: 69.97 ± 8.29). Km ranged from 41.00 to 46.50 D, with a mean of 43.94 ± 1.48D, and mean Q of the corneal surface was -0.15 ± 0.15. Six corneas showed a spherical design (Q= 0.0) and only one showed an aspheric design with Q = -0.50, generating an LSA of 0.0. Mean LSA of the corneal surface was +0.33 ± 0.14 µm. Only one eye showed an LSA equal to 0.0µm, and five showed an LSA of +0.10 to +0.30µm. No eye showed a negative LSA of the corneal surface. There was no correlation between Km and Q (r = -0.005 / p = 0.965) or between Km and LSA (r = 0.167 / p = 0.170). A correlation (r = 0.962 / p = 0.000) was observed between Q and LSA Conclusion: There was a correlation between Q and LSA of the corneal surface. There was no correlation between the sphericity coefficient or longitudinal spherical aberration with the average keratometry.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Cornea/anatomy & histology , Corneal Topography/methods , Organ Size , Contrast Sensitivity , Pupil , Medical Records , Cornea/physiology , Lens Implantation, Intraocular , Observational Study , Mathematics , Ocular Physiological Phenomena
19.
Rev. cuba. oftalmol ; 30(1): 0-0, ene.-mar. 2017. tab
Article in Spanish | LILACS | ID: biblio-901342

ABSTRACT

Objetivo: comparar los resultados visuales de los pacientes con cirugía refractiva corneal, operados de catarata e implante de lente intraocular, calculado por el método de Maloney y por Pentacam. Métodos: se realizó un estudio descriptivo, prospectivo y longitudinal en 41 ojos de 31 pacientes con catarata y antecedentes de cirugía refractiva corneal, divididos aleatoriamente en dos grupos (1 y 2) con 23 y 18 ojos respectivamente, para calcular el poder corneal por el método de Maloney y por Pentacam, respectivamente, necesario para el cálculo de la lente intraocular a implantar. Resultados: la mayoría de los pacientes tenía antecedentes de queratotomía radial (90,24 pr ciento). El poder dióptrico medio de la lente mediante el método de Maloney fue de 18,8 ± 4,20, mientras que con la lectura queratométrica, medida a 4,0 mm del Pentacam, fue de 18 ± 4,20, con una diferencia media de 0,80 dioptrías ( p= 0,000) asociada a la prueba de los rangos con signo de Wilcoxon. El componente esférico posoperatorio promedio fue de -0,49 ± 0,65 dioptrías en el grupo 1 y de -0,57 ± 0,685 en el grupo 2, con una diferencia entre la esfera observada y la esperada de 0,16 y 0,15 dioptrías respectivamente (p= 0,906), asociada a la prueba U de Mann-Whitney. quedaron emétropes un 43,48 por ciento del grupo 1 y un 50 por ciento del grupo 2. Conclusiones: ambos métodos brindan resultados visuales favorables, pero el cálculo de la lente intraocular a partir de las lecturas queratométricas aportadas por el Pentacam ofrece mejores resultados visuales para los pacientes con antecedentes de cirugía refractiva corneal(AU)


Objective: to compare the visual results of patients operated from cataract and with intraocular lens implantation through corneal refractive surgery and estimated by Maloney's method and Pentacam camera. Methods: prospective, longitudinal and descriptive study conducted in 41 eyes from 31 patients with cataract and history of refractive corneal surgery. They were randomly assigned to two groups (1 and 2) with 23 and 18 eyes, respectively in order to estimate the corneal power of the intraocular lens to be implanted through Maloney's method and Pentacam camera. Results: most of patients had history of radial keratotomy (90.24 percent). The average dioptric power of the lens according to Maloney's method was 18.8 ± 4.20 whereas the kerametric reading, measured at 4.0 mm from Pentacam was 18 ± 4.20, with a mean difference of 0.80 dioptries ((p= 0,000) associated to Wilcoxon's sign range test. The average postoperative spheral component was -0.49 ± 0.65 D in group 1 and -0.57 ± 0.685 in group 2, with a difference between the observed and the expected sphere of 0.16 and 0.15 dioptries, respectively (p= 0.906), associated to Mann-Whitney's U test. In group 1, 43.48 percent and in group 2, 50 percent remained emetropes. Conclusions: Both methods provide favorable visual results, but the calculation of the intraocular lens power through the keratometric readings by Pentacam offers better visual results for patients with a history of refractive corneal surgery(AU)


Subject(s)
Humans , Corneal Topography/methods , Keratotomy, Radial/methods , Lens Implantation, Intraocular/adverse effects , Epidemiology, Descriptive , Longitudinal Studies , Prospective Studies
20.
Arq. bras. oftalmol ; 79(6): 363-365, Nov.-Dec. 2016. tab
Article in English | LILACS | ID: biblio-838750

ABSTRACT

ABSTRACT Purpose: This study aimed to explore the effects of the Valsalva maneuver (VM) on ectatic corneas during anterior segment tomography scans using a Scheimpflug camera. Methods: This prospective observational study included 100 eyes of 50 patients with bilateral keratoconus (KC). Anterior segment tomography was first performed when the patients were in a resting position and immediately repeated as the participant performed VM. Scheimpflug images were taken using a Pentacam®. Results: The mean age of the participants was 24.14 ± 6.59 years. Of the 100 eyes included in the study, 7% had stage 1 KC, 47% had stage 2 KC, 32% had stage 3 KC, and 14% had stage 4 KC. The indices of KC were not significantly affected by VM. Similarly, no statistically significant differences were found between the stages of KC, or with the mean pachymetric progression index during VM. Pupil diameter showed a statistically significant increase during VM (p=0.017). There was a statistically significant decrease in the anterior chamber angle measurement during VM (p=0.001). Maximum curvature power in the front of the cornea decreased more during VM in stage 4 KC than for the other stages (p=0.014). Conclusions: No changes associated with VM were found in the KC indices or the stage of the disease. However, an increase in pupil diameter and a decrease in anterior chamber angle value were found. These changes were comparable to values obtained from previous studies performed on normal corneas.


RESUMO Objetivo: Este estudo tem como objetivo explorar os efeitos da manobra de Valsalva (VM) na córnea ectásica durante a varredura tomográfica do segmento anterior usando a câmera de Scheimpflug. Métodos: Foi conduzido estudo observacional, prospectivo envolvendo 100 olhos de 50 pacientes que apresentavam ceratocone (KC) bilateral. Tomografia do segmento anterior foi realizada inicialmente quando os pacientes estavam em posição de repouso e imediatamente depois, no curso de VM. Imagens de Scheimpflug foram feitas usando Pentacam®. Resultados: A média de idade dos participantes foi 24,14 ± 6,59 anos de idade. Dos olhos incluídos no estudo, 7% apresentava KC estágio 1,47% apresentava estágio 2,32% apresentava estágio 3, e 14% apresentava estágio 4. Índices de KC não foram significativamente afetadas pela VM. Não houve diferenças estatisticamente significativas com o estágio do KC, e o índice médio de progressão paquimétrica durante a VM. O diâmetro da pupila (PD) mostrou aumento estatisticamente significativo durante a VM (p=0,017). Houve diminuição estatisticamente significativa na medida do ângulo da câmara anterior durante a VM (p=0,001). O poder máximo de curvatura anterior da córnea no KC estágio 4 diminuiu mais do que os outros estágios durante o VM (p=0,014). Conclusões: Não foram encontradas alterações nos índices KC e no estágio da doença por causa da VM. Verificou-se que houve aumento na PD e uma diminuição no valor do ângulo da câmara anterior. Estas alterações foram comparáveis aos valores obtidos a partir de estudos realizados em córneas normais.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Photography/methods , Valsalva Maneuver/physiology , Cornea/diagnostic imaging , Corneal Topography/methods , Keratoconus/diagnosis , Anterior Chamber/diagnostic imaging , Prospective Studies , Disease Progression , Corneal Pachymetry/methods , Keratoconus/pathology , Keratoconus/diagnostic imaging
SELECTION OF CITATIONS